However, ECLS is typically not used as a bridge to heart transpla

However, ECLS is typically not used as a bridge to heart transplantation because of the limited duration of ECLS. In France, high-urgency priority heart transplantation remains a possibility

for transplant patients who are on ECLS. In this article, we present our experience with high-urgency priority heart transplantation after ECLS. From July 2004 to December 2009, 242 patients underwent emergent ECLS. Heart transplantation was performed in eight of these patients. Time of ECLS was 6.3 +/- 4.6 d. Before heart transplantation, all patients on ECLS had decreased organ dysfunctions and four were conscious. Despite frequent post-operative complications, no death occurred during the first year after transplantation. In our experience, ECLS is a valid method of supporting patients awaiting high-urgency heart transplantation and can be used as a short-term bridge to heart transplantation.”
“Systematic learn more excitation see more power and temperature-dependent measurements on the emission lines of single self-assembled InP/(Al0.20Ga0.80)(0.51)In0.49P quantum dots embedded in micropillars have been performed. The quantum dots were excited optically via a pulsed laser and their luminescence was collected using a micro-photoluminescence setup. The exciton and biexciton intensity,

linewidth, and spectral position was investigated in a temperature range from 4 K up to 130 K. Single-photon emission from the quantum dots is presented up to a temperature of 100 K, confirmed by photon-statistics measurements. (C) 2011 American Institute of Physics. [doi:10.1063/1.3633218]“
“We analyzed the effect of afferent input on patterns of brain electrical activation in a 31-year-old man with progressive myoclonic epilepsy (PME) by measuring the somatosensory evoked potential (SSEP) amplitude at the scalp after median nerve stimulation and examining the changes in the functional magnetic resonance imaging blood oxygen level-dependent (fMRI BOLD) signal. High-amplitude SSEPs were elicited at the wrist in association

with highly focal BOLD activation of the contralateral sensorimotor SCH 900776 price areas. By contrast, no diffuse activation of either the frontal or the posterior parietal cortical areas was observed, as seen in previously recorded data on SSEPs from a healthy control group. The highly focal BOLD activation in this patient suggests that cortex hyperexcitability might be limited to the sensorimotor cortex in PME. The combined EEG-fMRI findings highlight a dissociation between BOLD activation and neurophysiological findings. (C) 2011 Elsevier Inc. All rights reserved.”
“Redfield RR, Parsons RF, Rodriguez E, Mustafa M, Cassuto J, Vivek K, Noorchashm H, Naji A, Levine MH, Abt PL. Underutilization of A2 ABO incompatible kidney transplantation. ?Clin Transplant 2011 DOI: 10.1111/j.1399-0012.2011.01543.x. (C) 2011 John Wiley & Sons A/S. Abstract: Background: ABO compatibility creates a disadvantage for O and B renal allograft candidates.

Comments are closed.